User Profile
Collapse
-
Glad you were able to place your order when t-nuts came back on line. They have been a long time supporter of this forum.... -
It sounds very interesting that there's no damage to the cartridge and no damage to the blade If triggered. Not only can you get right back to work, but...
Last edited by LCHIEN; Yesterday, 08:10 PM.Leave a comment:
-
Offer of T-nuts still stands, -
Don't need a mill and lathe, Read my description of how to make your own.
I also have a article on the small T-nuts for the left hand slot...Last edited by LCHIEN; Yesterday, 08:10 PM.Leave a comment:
-
My requirement is that the throat plate must be at or just below the table surface at the front and just at or above the table in the back. That is so...
Leave a comment:
-
T-nuts.com seems to be not responding right now. Maybe give it a couple of days if there is a server problem. Not associated with T-nuts in any way...Leave a comment:
-
For a rip fence extension, on the rare occasion I need one, I use a four foot, or better, a 6' long level laid flat on the table next to the rip fence....
Last edited by LCHIEN; 09-11-2026, 09:26 AM.Leave a comment:
-
I made my own t nuts.
the slots are either a hair over 1" or a hair over 1.125" So an rectangle 1" x 1.125" would be universal...Last edited by LCHIEN; 09-11-2026, 09:59 AM.Leave a comment:
-
Oil prices just topped $100 per barrel. Not going to help.
...Leave a comment:
-
Here is the drawing in PDF, IIRC its one to one when you print it scaled full size on your printer (i.e. it can be used as a template). Verify the 1"...Last edited by LCHIEN; 09-08-2026, 10:06 AM.Leave a comment:
-
Here's some post experience notes
I cut the blanks, then routed the edge and end rabbets with the router and a straight bit or using the...Leave a comment:
-
-
Rain Frog???
In the electronics? Is this common? I don't even know what a rain frog is.
Ai says they are native to parts of Eastern...Last edited by LCHIEN; 08-24-2026, 11:57 PM.Leave a comment:
-
if you want a switch with improved safety, then get one of those magnetic tool switches.
They have the feature that when you turn it on it...Last edited by LCHIEN; 08-23-2026, 09:00 PM.Leave a comment:
-
I can offer a few ideas.
- One, the original switches were what engineers call two pole switches, DPDT to be exact. They only wired half the switch, using
Last edited by LCHIEN; 08-22-2026, 10:41 PM.Leave a comment:
-
well they didn't suggest it. They put up plastic sheeting barriers around the windows they were working on and that helped some. Overall keeping the... -
I had 17 new windows installed yesterday. For most of the day I had several 4x6 foot holes in my walls open to the outside when it was in the upper nineties....Leave a comment:
-
When I called the A/C service company it was Friday afternoon. Their first offer was, "Is Monday OK" to which I responded, "No," ...Leave a comment:
-
well something went right.
I know the AC worked fine yesterday. Today both of us went out and came back after noon. By 1:30 it seemed to be getting warm so I checked the AC and...Last edited by LCHIEN; 08-14-2026, 07:20 PM.👍 3
No activity results to display
Show More

LCHIEN
Leave a comment: